Cleaning and maintenance of ultrafiltration

Page view
[Abstract]:
The filter membrane activation layer is used to convert the polarity of the charged material to the same polarity as the bath itself. Its role is limited by time and its durability can reach several months under the best conditions. Of course, the activation layer affects the transmission excess.
The filter membrane activation layer is used to change the polarity of the charged material to the same polarity as the bath itself. Its role is limited by time and its durability can reach several months under the optimal conditions. Of course, the failure of the activation layer affects the permeability. excess. Therefore, the diaphragm activation layer must be cleaned and maintained regularly.
 
During the cleaning process and the fabrication of the diaphragm activation layer, you need to do serious work, be patient and reduce costs.
The premise of cleaning is that the ultrafiltration system should be thoroughly cleaned to no paint in each case! !! !!
Cleaning method: Cleaning method with additive Z (CPCS)
(1) Configure cleaning solution: 2% butyl, 3% ethyl glycol acetate, 0.5% formic acid, additive Z, and add it when the temperature reaches 40
(2) Matters needing attention
a. Temperature: The maximum temperature for cleaning is 55 ° C, and the cleaning is performed at intervals according to the hardness of the precipitate on the ultrafiltration membrane.
In other words, after the temperature drops, the cleaning liquid reaches the highest temperature again.
b. Pressure: During the cleaning process, the maximum pressure difference is 2 bar, and the maximum inlet pressure is 4 bar.
c. Apply the UF-P3 activation layer on the ultrafiltration membrane. The ultrafiltration equipment must be thoroughly cleaned. The significance of cleaning is to remove the residual cleaning solution.
d. It is meaningful to keep the deionized water of the cleaning solution at> 40 ° C.
e. The cleaning tank can also be performed in such a way that fresh deionized water is continuously introduced into the cleaning tank, and the amount introduced must correspond to the amount introduced into the wastewater equipment. It is important:> 40 ° C to ensure that the surfactant in the cleaning solution is dissolved.
f. After the equipment has been optimally cleaned, the system must be completely drained. Then, the UF-P3 solution was used to form an activated layer on the ultrafiltration membrane. It is important that the inlet and outlet pressures are almost equal at this time.