Dry adhesion |
||
Test requirements |
Testing standard |
detection result |
1, draw 100 grids with a spacing of 1mm |
0level |
0level |
2Pull with standard adhesive force (10 ± 1) n / 25mm tape |
||
3. pull with the minimum angle |
Wet adhesion |
||
Test requirements |
Testing standard |
detection result |
1. use pressure cooker with standard steam pressure gauge |
No blistering at level ≤ 1 |
0No blistering |
2Use deionized water with conductivity less than 10 μ s / C ㎡ |
||
3. the water temperature of the workpiece is 95-99 ℃ |
||
4. first draw a hundred grid with a spacing of 1mm |
||
5. the tested workpiece is suspended in the water and cannot touch the bottom of the pot or surface of the water |
||
6. keep the pressure at 0.1MPa for 2h |
||
7Take out the workpiece after 2h, and pull it with the standard adhesive force (10 ± 1) n / 25mm tape |
||
8. pull with the minimum angle |
100 grid pressure cooker test